Vis enkel innførsel

dc.contributor.authorTabase, Raphael Kubeba
dc.contributor.authorNæss, Geir
dc.contributor.authorLarring, Yngve
dc.date.accessioned2024-03-20T13:08:02Z
dc.date.available2024-03-20T13:08:02Z
dc.date.created2023-08-16T15:47:53Z
dc.date.issued2023
dc.identifier.citationTabase, R. K., Næss, G. & Larring, Y. (2023). Ammonia and methane emissions from small herd cattle buildings in a cold climate. Science of the Total Environment. 903. doi:en_US
dc.identifier.issn1879-1026
dc.identifier.urihttps://hdl.handle.net/11250/3123415
dc.description.abstractAmmonia (NH3) and methane (CH4) emission measurements that reflect local production conditions are required to track progress in national emission policies and verify emission factors. The findings can also be used to better understand key factors influencing emissions. This is especially important in Norway, which has long cold winters, and small cattle herds in mechanically ventilated buildings. However, until now, NH3 and CH4 emissions from Norwegian cattle buildings have not been reported in literature. Moreover, in other cold climates, NH3 and CH4 emissions are often taken from large dairy herds in naturally ventilated buildings, with less focus on suckler cows. The objectives were to assess indoor climate, report NH3 and CH4 emissions and examine the impact of climatic factors on NH3 and CH4 emissions in three small herd dairy and suckler cow buildings over three seasons. Three of the buildings had mechanical ventilation, while one was naturally ventilated. The suckler building had higher relative humidity (RH > 90 %) and NH3 concentrations (> 25 ppm) due to lower minimum air change rate (ACH = 1.2 h−1). The suckler building also had the highest NH3 emissions (2.04 g Livestock Unit (LU)−1 h−1) followed by the mechanically ventilated dairy building (1.92 g LU−1 h−1) with the highest ACH. These two buildings had the lowest stocking densities and floor areas. In contrast, the suckler building had the lowest CH4 emissions (6.8–10.7 g LU−1 h−1). Methane emissions from the dairy building with the supply-exhaust air mixing system (16.4–19.3 g LU−1 h−1) was higher than the other dairy buildings (11.7–13.8 g LU−1 h−1). Temperature influenced NH3 emissions however, the direction of association between temperature and NH3 emissions differed among buildings. Relationship between RH and NH3 emissions was positive, but the correlation coefficient (R2 = 0.67) was strongest in the building with the highest RH.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleAmmonia and methane emissions from small herd cattle buildings in a cold climateen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2023 The Author(s)en_US
dc.source.pagenumber14en_US
dc.source.volume903en_US
dc.source.journalScience of the Total Environmenten_US
dc.identifier.doi10.1016/j.scitotenv.2023.166046
dc.identifier.cristin2167463
dc.relation.projectNorges forskningsråd: 294857en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal